• Overview
  • Features and Benefits
  • Specifications
  • Accessories

Easy Consolidation

IT environments are often deployed with multiple storage infrastructures to accommodate for various types of data and achieve respective service levels. The scattered boxes for direct-attached storage (DAS), storage area network (SAN) and network-attached storage (NAS) configurations lead to poor utilization and complicated management. Infortrend offers EonNAS 5100 to support both file and block-based applications with a unified storage platform. EonNAS 5100U can simultaneously process data blocks transferred through IP and FC SAN and support file-sharing between Windows and Linux/Unix clients on Ethernet. Following the startup wizard, even IT generalists lacking storage expertise can easily initialize EonNAS 5100U to serve database, email and unstructured data while improving IT efficiency.

Simplified Management

Through an intuitive and user-friendly web-based interface, users can centrally configure, monitor, maintain and protect multiple EonNAS systems. EonNAS management software provides users with a complete system view ideal for monitoring long-term and real-time system status. Based on the analytic data, users can easily perform efficient tuning, accurate planning and quick troubleshooting. When any abnormal events are detected, the management software will automatically notify users so that proactive actions can be taken to prevent downtime. The comprehensive management features make it easy to optimize EonNAS 5100 for business production.

Flexible Scalability

The "scale as needed" flexibility of EonNAS 5100U allows users to future proof for tomorrow’s applications while satisfying their current needs. To increase performance, users can integrate low-latency SSDs for EonNAS systems to automatically enhance caching operations and in turn accelerate I/O processing. For capacity expansion, EonNAS 5100U can connect with expansion enclosures to accommodate a maximum of 84 drives. Its included thin-provisioning capability enables just-in-time resource allocation to optimize space utilization. Besides lowering total cost of ownership (TCO), the intelligent technology also simplifies management tasks of capacity planning and volume utilization tracking.

High Availability

To keep applications and services up and running, EonNAS 5100 is designed to operate with high-availability. Its redundant, hot-swappable hardware components of backend storage eliminate single point of failure. During drive failure, hardware-based RAID protection can ensure continuous accessibility to full integrity data. To protect valuable data sets against more critical threats, EonNAS 5100 also offers snapshot and replication functionality. In case the storage is damaged by logical errors, physical errors, or disasters, users are still able to obtain the highest data availability with minimized system downtime.

Features Benefits
Wide support of file and block storage protocols (CIFS, NFS, HTTP, FTP and  iSCSI) Seamlessly consolidate file and block storage for simplified management and efficient resource utilization
User-friendly management tools Minimize management overhead for system deployment, configuration and monitoring
Real-time analytics of system status Enable proactive problem handling and dynamic resource optimization
Redundant PSUs and cooling modules on backend storage Reduce system downtime induced by hardware failure

Data protection

      1. Hardware RAID
      2. Snapshot
      3. Volume Copy/Volume Mirror
      4. Sync and Async remote replication
Support the highest data availability and quick service restart after storage accidents
On-demand capacity scaling up to 60 drives with expansion enclosures "Pay as you grow" scalability; future proof for tomorrow’s applications while satisfying current needs
Thin provisioning Ensure the most efficient allocation of pooled capacity
Performance acceleration by integrating SSDs Enhance performance cost-effectively
Architecture
  1. Processor: One (1) Quad-Core Intel Xeon E5000 Series
  2. Cache Memory: Default 4GB, up to 12GB for the server node
  3. Default 512MB, up to 2GB for backend storage
  4. Connectivity: Four (4) 10/100/1000 Base-T Ethernet ports and two (2) 8G FC ports
Protocol Support
  1. NFS
  2. CIFS
  3. HTTP
  4. FTP
  5. iSCSI
  6. Fibre Channel Protocol (FCP)
Configuration Single node
Supported Drives*
  1. 500GB, 1TB or 2TB - 3.5" 7,200 RPM 3Gb/s SATA drives
  2. 300GB or 450GB - 3.5" 15,000 RPM 3Gb/s SAS drives
Drive Expansion Ports One (1) SAS expansion port
Expansion Enclosure (JBOD) S12S-J1000-G (12- SATA or SAS drives)
Max. Drives
  1. Per system: 12
  2. Via JBOD: 84
Supported Operating System
  1. Windows 2000
  2. Windows XP
  3. Windows Server 2008 (including Hyper-V)
  4. RedHat Enterprise Linux
  5. Sun Solaris
  6. FreeBSD
  7. IBM AIX
  8. HP-UX
  9. Mac OS X
  10. VMware
RAID Level 0, 1(0+1), 3, 5, 6, 10, 30, 50, 60
Data Compression LZJB
Data Services
  1. Snapshot
  2. Remote replication (1-to-1, 1-to-many or many-to-1)
  3. Thin provisioning
Management
  1. 10/100 Base-T Ethernet management port
  2. SNMP
  3. HTTPS
  4. System analytics
  5. Dashboard monitoring
  6. Configurable alerts
  7. Start-up wizard
Security
  1. Virus protection (ICAP-based virus scanning utility)
  2. Checksum data and metadata
Performance
  1. Read/Write acceleration with up to two (2) 32 or 64GB SSD
  2. Dynamic striping
Directory Services NIS, AD and LDAP
Backup Protocol NDMP
Networking
  1. IPv4, Static or DHCP
  2. IEEE 802.3AD LACP
Network Services NTP, DHCP, SMTP
Service and Support
(Warranty extension options available)

Standard Service

  1. 3-year limited hardware warranty and 8x5 phone, web and email support

Upgrade/Extension Options

  1. 3-year replacement part dispatch on the next business day
  2. Advanced Service: 3-year 24x7 phone, email and web support + onsite diagnostics on the next business day
  3. Premium Service: 3-year 24x7 phone, email and web support + onsite diagnostics in four hours
Form Factor 3U rackmount
Power

Dual redundant 650W power supplies for the server node

Backend storage:

  1. Power supplies: Dual redundant 530W DC
  2. AC voltage: 100VAC @ 10A/ 240VAC @ 5A with PFC (auto-switching)
  3. Frequency: 47-63 Hz
Dimension 131(H) x 446(W) x 650(D) mm
Weight(without HDDs) 36.5 kg

* Supported Drives vary by regions

Spare Parts

RAID controller module IFT-82SF18GF12P RAID controller module, for ES S12F-G1842P subsystem, SAS Exp.
RAID controller module IFT-82SF18GF12PMA RAID controller module, for ES S12F-G1842P subsystem, SAS Exp., 1GMB DDR-II RAM
RAID controller module IFT-82SF18GF12PMB RAID controller module, for ES S12F-G1842P subsystem, SAS Exp., 2GMB DDR-II RAM
RAID controller module IFT-82SF18GF12PMC RAID controller module, for ES S12F-G1842P subsystem, SAS Exp., 4GMB DDR-II RAM
IFT-DDR2RECMB 2GB DDR-II DIM module for EonStor G6 subsystems and EonNAS series.
Optical FC cable IFT-9270CFCCab01 Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 1Meter
IFT-9272CHandLLCD Left-side forearm handle, for ES 2U series subsystems, LCD panel included
IFT-9272CHandR Right-side forearm handle, for ES 2U series subsystems
IFT-9272CPSU Power supply module, for ES 2U DDR-interface subsystems, 350W capacity
Small Form Pluggable Optical Transceiver IFT-9370CSFP8G Avago Fibre Channel 8.5 / 4.25 / 2.125 GBd Small Form Pluggable OpticalTransceiver, LC, wave-length 850nm, multi-mode
Slide rail assembly IFT-9373CSlider36 Slide rail assembly, for all EonStor G6 subsystems, 24"~36" rack depth
Drive tray IFT-9273CDTray Drive tray, Type-III bezel and Type-II LED lightpipe
Drive tray (Type-III bezel and Type-II LED lighpipe) IFT-9273S1DT2S1S Drive tray (Type-III bezel and Type-II LED lighpipe), 2 SAS-to-1 SATA (SATA-II) MUX conversion, active-active port selector embedded, dual-controller subsystems, Rev. 1.2
  IFT-9NS51CPSU Power Supply Unit for EonNAS 5100 series
  IFT-H7250HA2161 Hitachi SATA II HDD(HDE721050SLA330)(0A38025)(Microcode:3AA),500GB,7200RPM,MLC:BA3120,Buffer 32MB,HW verison:0
  IFT-9NS51Tray1 3.5" Drive tray for EonNAS 5100 series
  IFT-9NS51Tray2 3.5" Drive tray to accommodate 2.5" drives for EonNAS 5100 series

Accessories

IFT-9373CBBU Battery backup unit, Li-Ion, forEonStor G6 series subsystems, BBU ID
IFT-9373CCBM Cashe backup module, Li-lon, Flash, for EonStor G6 series subsystems, BBU ID
IFT-9272CFanModE Cooling fan module, for ES 2U DDR-interface subsystems
Optical FC cable IFT-9270CFCCab02 Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 5 Meters
Optical FC cable IFT-9270CFCCab03 Optical FC cable, LC-LC, MM-62.5/125, Duplex, LSZH, O.D.=1.8mm*2, 10 Meters
RS-232C cable IFT-9373ASCAB RS-232C cable, DB9 to DB9
SAS external cable

IFT-9270CMSASCAB3

SAS external cable, SFF-8470 to SFF-8088, 50 Centimeters
SAS external cable

IFT-9270CMSASCAB4

SAS external cable, SFF-8470 to SFF-8088, 120 Centimeters
SAS external cable

IFT-9270CMSASCAB5

SAS external cable, SFF-8470 to SFF-8088, 170 Centimeters
IFT-9370CSFP8G Avago Fibre Channel 8.5 / 4.25 / 2.125 GBd Small Form Pluggable Optical Transceiver, LC, wave-length 850nm, multi-mode
  IFT-9372CFANMODE Cooling fan module, for EonStor G6 2UG/12-bay subsystems
  IFT-HXX32NA2XX1 SLC SATA SSD, 32GB, 1 in 1 Packing
  IFT-BH1ITE111 HBA,EXPI9402PT,iSCSI/1G,Dual port,PCI-E,1-pack
  IFT-BH1ITE110 HBA,EXPI9404PTL,iSCSI/1G,Quad port,PCI-E,1-pack
  IFT-BH1QGF210 HBA,QLE2562,FC-8G,Dual port,PCI-E,1-pack.